The closed contour of cooling with the nonfreezing liquid circulating under pressure contains a radiator, the pump of cooling liquid, a broad tank, the thermostat and the fan with the electric motor operated by the thermoswitch located in a thermostat cover.
Radiator
The radiator with a cross stream has the heat exchanger from alloy of aluminum and tanks from artificial material.
Broad tank
The broad tank from artificial material, in a stopper has the valve of bilateral action.
Pump of cooling liquid
The centrifugal pump of cooling liquid is put in action by a gear belt of the drive of system of gas distribution.
Thermostat
The wax thermostat is located sideways heads of the block of cylinders.
Temperature began opening: 84 ° –89 °C.
Temperature of full opening: 102±3 °C.
Fan
The fan is put in action by the electric motor operated by the thermoswitch located in a thermostat cover.
Cooling liquid
Quantity: 8,6 dm3.
Type: mix of 60% of the distilled water and 40% of the special nonfreezing mix Motorcraft with the designation Ford SSM 97 B 9103 A.
Frequency of replacement: each 3 years. |